Loopback Test (Function Code: 08 Hex)
The loopback test returns command messages directly as response messages without changing the contents to
check the communications between the master and slave. You can set user-defined test code and data values.
The following table shows a message example when performing a loopback test with the slave 1 Inverter.
Command Message
Slave address
Function code
Higher
place
Test Code
Lower
place
Higher
A5H
place
Data
Lower
place
Higher
DAH
place
CRC-16
Lower
8DH
place
Writing to Multiple Storage Registers (Function Code: 10 Hex)
Write the specified data to each specified storage register from the specified addresses. The written data must
be in the following order in the command message: Higher place 8 bits, then lower place 8 bits, in storage reg-
ister address order.
The following table shows an example of a message when forward operation has been set at a frequency refer-
ence of 60.0 Hz in the slave 1 Inverter by the PLC.
Command Message
Slave Address
Function Code
Higher
Start
place
Address
(register
Lower
number)
place
Higher
place
Quantity
(10H max.)
Lower
place
Number of attached
data bytes
Higher
place
Lead data
Lower
place
Higher
place
Next data
Lower
place
Higher
place
CRC-16
Lower
place
Response Message
(Normal Message)
01H
Slave address
08H
Function code
Higher
00H
place
Test Code
Lower
00H
place
Higher
place
Data
Lower
37H
place
Higher
place
CRC-16
Lower
place
Response Message
(Normal Message)
01H
Slave Address
10H
Function Code
Higher
00H
place
Start
Address
Lower
01H
place
Higher
00H
place
Quantity
Lower
02H
place
Higher
04H
place
CRC-16
Lower
00H
place
01H
02H
58H
63H
39H
Communications Functions
Response Message
(Error Message)
01H
Slave address
08H
Function code
00H
Error Code
Higher
00H
place
CRC-16
Lower
A5H
place
Note The MSB of the function code will be
37H
set to 1 when an error occurs.
DAH
8DH
Response Message
(Error Message)
01H
Slave Address
10H
Function Code
00H
Error code
Higher
01H
place
CRC-16
Lower
00H
place
Note The MSB of the function code will be
02H
set to 1 when an error occurs.
10H
08H
01H
88H
01H
86H
50H
01H
90H