Omron SYSDRIVE 3G3RV Series User Manual page 158

High-function general-purpose inverters
Table of Contents

Advertisement

Name
Param-
eter
LCD
Num-
Display
ber
Max.
output
frequency
E1-04
Max
Frequency
Max.
voltage
E1-05
Max
Voltage
Base
frequency
E1-06
Base
Frequency
Mid.
output
frequency
E1-07
Mid
Frequency
A
Mid.
output
frequency
E1-08
voltage
Mid
Voltage A
Min.
output
frequency
E1-09
Min
Frequency
Min.
output
frequency
voltage
E1-10
Min
Voltage
-32
5
Description
Output voltage (V)
Frequency (Hz)
To set V/f characteristics in a
straight line, set the same values
for E1-07 and E1-09. In this case,
the setting for E1-08 will be disre-
garded.
Always ensure that the four fre-
quencies are set in the following
manner:
E1-04 (FMAX) ≥ E1-06 (FA) >
E1-07 (FB) ≥ E1-09 (FMIN)
Output voltage (V)
Frequency (Hz)
To set V/f characteristics in a
straight line, set the same values
for E1-07 and E1-09. In this case,
the setting for E1-08 will be disre-
garded.
Always ensure that the four fre-
quencies are set in the following
manner:
E1-04 (FMAX) ≥ E1-06 (FA) >
E1-07 (FB) ≥ E1-09 (FMIN)
Control Methods
Change
during
Setting
Factory
Range
Setting
Opera-
V/f
tion
60.0
Hz
40.0 to
*2
(50.0
No
Q
400.0
Hz)
*5
*6
200.0
0.0 to
V
No
Q
255.0
*1*2
*1
60.0
Hz
0.0 to
*2
No
Q
400.0
(50.0
Hz)
*6
0.0 to
3.0 Hz
No
A
400.0
*2
0.0 to
15.0 V
No
A
*1
*1 *2
255
0.0 to
1.5 Hz
No
Q
400.0
*2
0.0 to
9.0 V
No
A
255.0
*1 *2
*1
V/f
Register
Page
Open
with
Loop
PG
Q
Q
303H
6-129
Q
Q
304H
6-129
Q
Q
305H
6-129
A
A
306H
6-129
4-19
A
A
307H
6-129
Q
Q
308H
6-129
4-18
A
A
309H
4-19
6-129

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sysdrive 3g3rv-a2004Sysdrive 3g3rv-a2004-eSysdrive 3g3rv-a2007Sysdrive 3g3rv-a2007-eSysdrive 3g3rv-a2015Sysdrive 3g3rv-a2015-e ... Show all

Table of Contents