Parameter Tables; A: Setup Settings - Omron SYSDRIVE 3G3RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

Parameter Tables

K K K K

A: Setup Settings

The following settings are made with the environment parameters (A parameters): Language displayed on the
Digital Operator, access level, control method, initialization of parameters.
n Initialize Mode: A1
Parameters for the environment modes are shown in the following table.
Name
Param-
LCD
eter
Number
Display
Language
selection for
Digital
Operator
display
A1-00
Select Lan-
guage
Parameter
access level
A1-01
Access
Level
Control
method
selection
A1-02
Control
Method
Description
Used to select the language
displayed on the Digital
Operator (LED).
0: English
1: Japanese
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
This parameter is not initial-
ized by the initialize opera-
tion.
Used to set the parameter
access level (set/read.)
0: Monitoring only
(Monitoring drive mode
and setting A1-01 and
A1-04.)
1: Used to select parameter
(Only parameters set in
A2-01 to A2-32 can be
read and set.)
2: Advanced
(Parameters can be read
and set in both quick
programming mode and
advanced programming
(A) mode.)
Used to select the control
method for the Inverter
0: V/f control
1: V/f with PG feedback
(Pulse generator as
encoder)
2: Open loop vector
This parameter is not initial-
ized by the initialize opera-
tion.
Control Methods
Change
during
Setting
Factory
Range
Setting
Opera-
V/f
tion
0 to 6
1
Yes
A
0 to 2
2
Yes
A
0 to 2
0
No
Q
Parameter Tables
V/f
Register Page
Open
with
Loop
PG
A
A
100H
-
6-141
A
A
101H
6-142
4-7
Q
Q
102H
4-9
4-18
9
5-