nMotor 2 Setup: E4
Parameters for motor 2 are shown in the following table.
Name
Param-
LCD
eter
Number
Display
Motor 2
Sets the motor rated current
rated cur-
in 1 A units.
rent
These set values will become
the reference values for
E4-01
motor protection, torque lim-
Motor
its and torque control.
Rated FLA
This parameter is automati-
cally set during autotuning.
Motor 2
Sets the motor rated slip in
rated slip
Hz units.
These set values will become
E4-02
the reference values for slip
Motor
compensation.
Rated Slip
This parameter is automati-
cally set during autotuning.
Motor 2 no-
Sets the motor no-load cur-
load current
rent in 1 A units.
E4-03
This parameter is automati-
No-Load
cally set during autotuning.
Current
Motor 2
number of
Sets the number of motor
poles (num-
poles.
E4-04
ber of poles)
This parameter is automati-
cally set during autotuning.
Number of
Poles
Motor 2
Sets the motor phase-to-
line-to-line
phase resistance in Ω units.
resistance
E4-05
This parameter is automati-
Term Resis-
cally set during autotuning.
tance
Motor 2
Sets the voltage drop due to
leak induc-
motor leakage inductance as
tance
a percentage of the motor
E4-06
rated voltage.
Leak Induc-
This parameter is automati-
tance
cally set during autotuning.
Motor 2
Set the rated output of the
rated capac-
motor in units of 0.01 kW.
ity
E4-07
This parameter is automati-
Mtr Rated
cally set during autotuning.
Power
* 1. The factory setting depends upon the Inverter capacity. The value for a 200-V class Inverter of 0.4 kW is given.
* 2. The setting range is 10% to 200% of the Inverter's rated output current. The values for a 200-V class Inverter of 0.4 kW is given.
* 3. If a multi-function input is set for motor 2 (H1- @@ = 16), the factory setting will depend upon the Inverter capacity. The value for a 200-V class
Inverter of 0.4 kW is given.
Setting
Description
Range
0.32
to 6.40
*2
0.00 to
20.00
0.00 to
1.89
*3
2 to 48 4 poles
0.000
to
65.000
0.0 to
40.0
0.40 to
650.00
Control Methods
Change
V/f
during
Factory
Setting
Opera-
V/f
with
tion
PG
1.90 A
No
A
A
*1
2.90
No
A
A
Hz
*1
1.20 A
No
A
A
*1
No
No
A
9.842
No
A
A
*1
18.2%
No
No
No
*1
0.40
No
A
A
*1
Parameter Tables
Register Page
Open
Loop
A
321H
6-47
A
322H
-
A
323H
-
No
324H
-
A
325H
-
A
326H
-
A
327H
-
37
5-

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sysdrive 3g3rv-a2004Sysdrive 3g3rv-a2004-eSysdrive 3g3rv-a2007Sysdrive 3g3rv-a2007-eSysdrive 3g3rv-a2015Sysdrive 3g3rv-a2015-e ... Show all

Table of Contents