Using Multi-Step Speed Operation - Omron SYSDRIVE 3G3RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

K K K K

Using Multi-Step Speed Operation

With SYSDRIVE RV series Inverters, you can change the speed to a maximum of 17 steps, using 16 fre-
quency references, and one jog frequency reference.
The following example of a multi-function input terminal function shows a 9-step operation using multi-step
references 1 to 3 and jog frequency selection functions.
nRelated Parameters
To switch frequency references, set multi-step references 1 to 3 and the jog reference selection in the multi-
function contact inputs.
Multi-function Digital Inputs (H1-01 to H1-05)
Terminal
S4
S5
S6
S7
Multi-step Speed by Combining Multi-Function Digital Inputs
The speed can be changed by combining the ON/OFF status of S4 to S7 (multi-function digital input termi-
nals) to set multi-step speed references 1 to 3 and the jog frequency selection. The following table shows the
possible combinations.
Speed
1
2
3
4
5
6
7
8
9
* Terminal S7's jog frequency selection is given priority over multi-step speed references.
-10
6
Parameter
Set Value
Number
H1-02
3
H1-03
4
H1-04
5
H1-05
6
TerminalS4
TerminalS5
TerminalS6
Multi-step
Multi-step
Speed Refer-
Speed Refer-
Speed Refer-
ence 1
ence 2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
-
-
Multi-step speed reference 1 (Also used for master speed/auxiliary speed switching when
multi-function analog input H3-09 is set to 2 (auxiliary frequency reference).)
Multi-step speed reference 2
Multi-step speed reference 3
Jog frequency selection (given priority over multi-step speed reference)
TerminalS7
Multi-step
Jog Fre-
quency
ence 3
Selection
OFF
OFF
Frequency reference 1 d1-01, master speed frequency
OFF
OFF
Frequency reference 2 d1-02, auxiliary frequency
OFF
OFF
Frequency reference 3 d1-03
OFF
OFF
Frequency reference 4 d1-04
ON
OFF
Frequency reference 5 d1-05
ON
OFF
Frequency reference 6 d1-06
ON
OFF
Frequency reference 7 d1-07
ON
OFF
Frequency reference 8 d1-08
*
-
Jog frequency d1-17
ON
Details
Selected Frequency

Advertisement