nAdjusting the Pulse Monitor Items
Adjust the pulse frequency output from pulse monitor terminal MP-SC. Set the pulse frequency output when
100% frequency is output to H6-07.
Set H6-06 to 2, and H6-07 to 0, to output the frequency synchronous with the Inverter's U-phase output.
nApplication Precautions
When using a pulse monitor parameter, connect a peripheral device according to the following load condi-
tions. If the load conditions are different, there is a risk of characteristic insufficiency or damage to other
devices.
Using a Sourcing Output
Output Voltage (Iso-
lated)
VRL (V)
+5 V min.
+8 V min.
+10 V min.
Using a Sinking Input
External Power Supply
(V)
Sink Current (mA)
Load Impedance (kΩ)
1.5 kΩ min.
3.5 kΩ min.
10 kΩ min.
12 VDC±10%,
15 VDC±10%
16 mA Max
Monitor Parameters
Load impedance
MP
VRL
AC
External power supply
Load impedance
MP
Sinking current
AC
75