Omron SYSDRIVE 3G3RV Series User Manual page 170

High-function general-purpose inverters
Table of Contents

Advertisement

nCommunications Option Cards: F6
Parameters for a Communications Option Card (DeviceNet) are shown in the following table.
Param-
eter
Number
Display
DeviceNet
fault opera-
tion selec-
tion
F6-01
Comm Bus
Flt Sel
Communi-
cations
external
fault input
detection
F6-02
method
selection
EF0 Detec-
tion
Communi-
cations
external
fault input
operation
F6-03
selection
EF0 Fault
Action
Not used
F6-04
Trace Sam-
ple Tim
Display unit
selection for
current
F6-05
monitor
Current
Unit Sel
Note For details on Communications Option Cards, refer to the manual for each Option Card (DeviceNet Communications Card/3G3FV-PDRT1-SIN (Cat.
No. I525-E1)).
* 1. If F6-01 or F6-03 is set to 3, the Inverter will continue operating. Be sure to install a limit switch or an emergency stop switch as a safety precaution.
* 2. For (-E) models.
-44
5
Name
Description
LCD
0: Decelerates to a stop
using C1-02 deceleration
time/fault detection
1: Coast to a stop/fault
detection
2: Decelerates to stop using
C1-09 deceleration time/
fault detection
3: Continues operating/
alarm detection
0: Fault detection during
power ON
1: Fault detected during
running only (when RUN
commands are input)
0: Decelerates to a stop
using C1-02 deceleration
time/fault detection
1: Coast to a stop/fault
detection
2: Decelerates to a stop
using C1-09 deceleration
time/fault detection
3: Continues operating/
alarm detection
Do not set.
0: Amperes
1: 100%/8192
Setting
Factory
Range
Setting
0 to 3
1
*1
0 or 1
0
0 to 3
1
*1
-
0
0 or 1
0
Control Methods
Change
V/f
during
Open
Opera-
V/f
with
Loop
tion
PG
No
A
A
A
No
A
A
A
No
A
A
A
No
A
A
A
*2
*2
*2
No
A
A
A
Register Page
3A2H
-
3A3H
-
3A4H
-
3A5H
-
3A6H
-

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sysdrive 3g3rv-a2004Sysdrive 3g3rv-a2004-eSysdrive 3g3rv-a2007Sysdrive 3g3rv-a2007-eSysdrive 3g3rv-a2015Sysdrive 3g3rv-a2015-e ... Show all

Table of Contents