Type
Name
Special Mounted
Fan Unit
Options
Scaling Meter
Analog Operator (stan-
Separately
dard with steel panels)
Installed Options
Analog Operator (small,
plastic)
Braking Unit
Braking Resistor Unit
Braking Resistor
Special Options
DC Reactor
Digital Operator with
LCD Display
Digital Operator with
LED Display
Digital Operator Connec-
tion Cable
Analog Monitor Cards*2
Option Cards
PG Speed Control Cards
DeviceNet Communica-
tions Card
AC Reactor (Yaskawa)
Simple Input Noise Filter
(Yaskawa)
Recommended
Separately
Input Noise Filter
Installed
(Schaffner)
*1
Options
Input Noise Filter
(Schaffner) for EMC
Directive
Output Noise Filter
(Tokin)
* 1. Recommended Options can be ordered from OMRON using the above model numbers.
* 2. Not applicable to (-E) models.
Table 9.1 Options and Peripheral Devices
Model number
Replacement fan for Inverters equipped with a cooling fan.
3G3IV-PFAN @
Replace the Cooling Fan when the fan replacement time has come or a cooling fan fault
(FAN) alarm has been displayed.
Connects to a multi-function analog output from the Inverter.
K3TJ-V11 @
Used to display rotational speeds of motors, line speeds, etc., in physical units.
Allows frequency reference settings and ON/OFF operation control to be performed by
3G3IV-PJVOP96 @
analog references from a remote location (50 m max.).
Frequency counter specifications: 75 Hz, 150 Hz, 220 Hz
Allows frequency reference settings and ON/OFF operation control to be performed by
3G3IV-PJVOP95 @
analog references from a remote location (50 m max.).
Frequency counter specifications: 60/120 Hz, 90/180Hz
Used with a Braking Resistor Unit to reduce the deceleration time of the motor.
3G3IV-PCDBR @ B
Not required with Inverters of 7.5 kW or less for 200-V class Inverters or for Inverters of
15 kW or less for 400-V class Inverters.
Consumes the regenerative motor energy with a resistor to reduce deceleration time (use
3G3IV-PLKEB @
rate: 10% ED).
Consumes the regenerative motor energy with a resistor to reduce deceleration time (use
rate: 3% ED).
3G3IV-PERF150WJ @ 01
Not required with Inverters of 3.7 kW or less for 200-V class Inverters or for Inverters of
2.2 kW or less for 400-V class Inverters.
Used to control harmonics generated by the Inverter and to improve the input power fac-
3G3HV-PUZDAB @
tor of the Inverter. All Inverters of 18.5 kW or higher contain built-in DC reactors.
3G3IV-PJVOP160
Displays messages on an LCD.
3G3IV-PJVOP161
Display messages on an LED display. Standard in Asia and Europe.
3G3IV-PCN126 (1 m)
Extension cable to use a 3G3RV-series Digital Operator remotely.
Cable length: 1 m or 3 m
3G3IV-PCN326 (3 m)
The resolution of the analog output from the Inverter is 11 bits. Use this Card if there are
3G3IV-PAO08
not enough analog outputs.
The output resolution of the 3G3IV-PAO08 is (0 to 10 V output for frequency meters or
output current meters) and the output resolution of the 3G3IV-PAO12 is 1/2048 (0 to
3G3IV-PAO12
10 V for control applications).
Phase-A (single-phase) pulse input and open collector output for V/f control with a PG.
3G3FV-PPGA2
Maximum response frequency: 30 kHz, with pulse monitor output.
Phase-A/B pulse inputs and open collector output for flux vector control.
3G3FV-PPGB2
Maximum response frequency: 30 kHz, with pulse monitor output.
Phase-A (single-phase) pulse input and line driver output (RS-422) for V/f control with a PG.
3G3FV-PPGD2
Maximum response frequency: 300 kHz, with pulse monitor output.
Phase-A/B/Z pulse inputs and line driver output (RS-422) for flux vector control.
3G3FV-PPGX2
Maximum response frequency: 300 kHz, with pulse monitor output
Used for DeviceNet communications with a Programmable Controller or other
3G3FV-PDRT1-SIN
DeviceNet master device.
Used to control harmonics generated by the Inverter or when the power supply capacity
3G3IV-PUZBAB @
is greatly larger than the Inverter's capacity. Also used to increase the power factor.
Reduces noise coming into the inverter from the power supply line and to reduce noise
3G3EV-PLNFD @
flowing from the inverter into the power supply line. Connected to the power supply
input side.
Reduces noise coming into the inverter from the power supply line and to reduce noise
3G3IV-PFN @
flowing from the inverter into the power supply line.Connected to the power supply
input side.
3G3RV-PFSo
Required for the 3GRV Inverter to meet the EMC Directive.
Controls noise generated by the Inverter so it does not enter the power supply. Con-
3G3IV-PLF @
nected to the motor output side.