nRemoving the Front Cover
Press the left and right sides of the front cover in the directions of arrows 1 and lift the bottom of the cover in
the direction of arrow 2 to remove the front cover as shown in the following illustration.
nMounting the Front Cover
After wiring the terminals, mount the front cover to the Inverter by performing in reverse order the steps to
remove the front cover.
1. Do not mount the front cover with the Digital Operator attached to the front cover; otherwise, the Digital
Operator may malfunction due to imperfect contact.
2. Insert the tab of the upper part of the front cover into the groove of the Inverter and press the lower part of
the front cover onto the Inverter until the front cover snaps shut.
nMounting the Digital Operator
After attaching the terminal cover, mount the Digital Operator onto the Inverter using the following procedure.
1. Hook the Digital Operator at A (two locations) on the front cover in the direction of arrow 1 as shown in
the following illustration.
2. Press the Digital Operator in the direction of arrow 2 until it snaps in place at B (two locations).
-20
1
Fig 1.16 Removing the Front Cover (3G3RV-A4055 Shown Above)
1
2
Fig 1.17 Mounting the Digital Operator
A
B