Name
Param-
eter
Num-
Display
ber
Motor 2
min. out-
put fre-
quency
voltage
(VMIN)
E3-08
Min Volt-
age
* 1. These are values for a 200-V class Inverter. Values for a 400-V class Inverter are double.
* 2. The factory setting will change when the control method is changed. (V/f control factory settings are given.)
* 3. When C6-01 is set to 0, the upper limit of the setting range is 150.0 Hz.
* 4. For (-E) models. Factory setting for base frequency is 50 Hz.
-36
5
Description
LCD
Output voltage (V)
To set V/f characteristics in a
straight line, set the same values
for E3-05 and E3-07.
In this case, the setting for E3-06
will be disregarded.
Always ensure that the four fre-
quencies are set in the following
manner:
E3-02 (FMAX) ≥ E3-04 (FA) >
E3-05 (FB) > E3-07 (FMIN)
Setting
Factory
Range
Setting
0.0 to
Frequency (Hz)
9.0 V
255.0
*1
*1
Control Methods
Change
V/f
during
Open
Opera-
V/f
with
Loop
tion
PG
No
A
A
A
Register
Page
320H
-

Advertisement

Table of Contents

Troubleshooting