Name
Param-
eter
LCD
Num-
Display
ber
Mid.
output
frequency
2
E1-11
Mid
Frequency
B
Mid.
Set only to fine-adjust V/f for the
output
output range. Normally, this setting
frequency
is not required.
E1-12
voltage 2
Mid
Voltage B
Base
voltage
E1-13
Base
Voltage
* 1. These are values for a 200-V class Inverter. Values for a 400-V class Inverter are double.
* 2. The factory setting will change when the control method is changed. (V/f control factory settings are given.)
* 3. E1-11 and E1-12 are disregarded when set to 0.0.
* 4. E1-13 is set to the same value as E1-05 by autotuning.
* 5. When C6-01 is set to 0, the upper limit of the setting range is 150.0 Hz.
* 6. For (-E) models. Factory setting for base frequency is 50 Hz.
nMotor Setup: E2
Parameters for motor 1 are shown in the following table.
Name
Param-
LCD
eter
Number
Display
Motor rated
Sets the motor rated current
in 1 A units.
current
These set values will become
the reference values for
E2-01
motor protection and torque
Motor
limits.
Rated FLA
This parameter is automati-
cally set during autotuning.
Sets the motor rated slip in
Motor rated
Hz units.
slip
These set values will become
E2-02
the reference values for slip
Motor
compensation.
Rated Slip
This parameter is automati-
cally set during autotuning.
Motor no-
Sets the motor no-load cur-
load current
rent in 1 A units.
E2-03
This parameter is automati-
No-Load
cally set during autotuning.
Current
Number of
Sets the number of motor
motor poles
poles.
E2-04
This parameter is automati-
Number of
cally set during autotuning.
Poles
Setting
Description
Range
0.0 to
400.0
0.0 to
255.0
*1
0.0 to
255.0
*1
Setting
Description
Range
0.32 to
6.40
*2
0.00 to
20.00
0.00 to
1.89
*3
2 to 48 4 poles
Control Methods
Change
V/f
during
Factory
Setting
Opera-
V/f
with
tion
PG
0.0 Hz
No
A
A
*3
0.0 V
No
A
A
*3
0.0 V
No
A
A
*4
Control Methods
Change
V/f
during
Factory
Setting
Opera-
V/f
with
tion
PG
1.90 A
No
Q
Q
*1
2.90
No
A
A
Hz
*1
1.20 A
No
A
A
*1
No
No
Q
Parameter Tables
Register
Page
Open
Loop
A
30AH
6-129
A
30BH
6-129
Q
30CH
6-129
Register Page
Open
Loop
6-47
Q
30EH
6-127
A
30FH
6-127
A
310H
6-127
No
311H
6-127
33
5-