Param-
eter
Num-
ber
Password setting
A1-05
Select Password
nSetting Precautions
Parameter A1-05 cannot be displayed using normal key operations. To display A1-05, hold down the RESET
Key and press the MENU Key while A1-04 is displayed.
K K K K
Displaying User-set Parameters Only
You can set and refer to parameters necessary to the Inverter only, using the A2 parameters (user-set parame-
ters) and A1-01 (Parameters Access Level).
Set the number of the parameter to which you want to refer in A2-01 to A2-32, and then set A1-01 to 1. You
can set and refer to parameters set in A1-01 to A1-03 and A2-01 to A2-32 only, using advanced programming
mode.
nRelated Parameters
Param-
eter
Num-
ber
User setting parameters
A2-01
to
A2-32
User Param 1 to 32
-142
6
Name
LCD Display
Used to set a four digit number as the password.
This parameter is not usually displayed. When the
password (A1-04) is displayed, hold down the
RESET Key and press the Menu Key and the pass-
word will be displayed.
Name
LCD Display
Used to set the parameter numbers that can be set/
read. Maximum 32.
Effective when the access level (A1-01) is set to
User Program (1). Parameters set in A2-01 to A2-
32 can be set/read in programming mode.
Setting
Description
Range
0 to
9999
Setting
Description
Range
b1-01
o2-08
Control Methods
Change
Factory
during
Setting
Opera-
V/f
tion
0
No
A
Control Methods
Change
Factory
during
Setting
Opera-
V/f
tion
to
-
No
A
Open
V/f
Loop
with
Vec-
PG
tor
A
A
Open
V/f
Loop
with
Vec-
PG
tor
A
A