The data tables are shown below. The types of data are as follows: Reference data, monitor data, and broadcast
data.
Reference Data
The reference data table is shown below. You can both read and write reference data.
Register No.
0000H
0001H
0002H
0003H to 0005H Not used
0006H
0007H
0008H
0009H
000AH to 000EH Not used
-84
6
Set the number of data specified using command messages as quantity of specified messages x 2. Handle
response messages in the same way.
Reserved
Frequency reference
Bit 0
Run/stop command
Bit 1
Forward/reverse operation
Bit 2
External error
Bit 3
Error reset
Bit 4
ComNet
Bit 5
ComCtrl
Bit 6
Multi-function input command 3
Bit 7
Multi-function input command 4
Bit 8
Multi-function input command 5
Bit 9
Multi-function input command 6
Bit A
Multi-function input command 7
Bits B to F
Not used
Frequency reference (Set units using parameter o1-03)
PID target value
Analog output 1 setting (-11 V/-726 to 11 V/726)
Analog output 2 setting (-11 V/-726 to 11 V/726)
Multi-function contact output setting
Bit 0
Contact output (Terminal M1-M2)
Bit 1
PHC1(Contact P1-PC)
Bit 2
PHC2(Contact P2-PC)
Bits 3 to 5
Not used
Bit 6
Set error contact (terminal MA-MC) output using bit 7. 1: ON 0: OFF
Bit 7
Error contact (terminal MA-MC)
Bits 8 to F
Not used
Contents
1: Run 0: Stop
1: Reverse 0: Forward
1: Error (EFO)
1: Reset command
1: ON 0: OFF
1: ON 0: OFF
1: ON 0: OFF
1: ON 0: OFF