14. Mechanical adjustment
14.3 PH unit mechanical adjustment
14.3.1
Skew adjustment
This adjustment must be made in the following case:
• When PH unit is replaced.
4. Touch [Service Mode] → [Imaging Process Adjustment] → [Stabilizer] → [Initialize +
Image Stabilization].
5. After image stabilization is completed, display [Service Mode] → [State Confirmation] →
[Color Regist] and check if the Step Value: X of each color C, M, Y, is within the specifi-
cation.
Specification: within ± 4
460
1. Turn ON the main power switch.
2. Select [Service Mode] → [Test
Mode] → [Gradation Pattern] and out-
put the test pattern with the following
conditions.
Conditions: SINGLE, HYPER,
3. Using the output test pattern, check
if each color of CMYK is printed in
correct pattern.
If the pattern is not correct, any trou-
bles such as connecting failure in PH
A02EF3E524DA
unit of the corresponding color may
occur, which should be modified.
If there is not any problem, proceed
to step 4.
Field Service Ver. 3.0 Jan. 2008
Gradation, 4 Color
A02EF3E525DA