Trouble Isolation - Konica Minolta bizhub C353 Service Manual

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

Field Service Ver. 3.0 Jan. 2008
10.8.9

Trouble Isolation

Functions
• Individual units and options have a set or unset setting for the trouble isolation func-
tion.
Use
• When a problem occurs, this function enables the continuous use of the units that are
not affected by separately controlling them and isolating other units that have a prob-
lem.
• The machine isolates only units that have a "set" setting.
NOTE
• The malfunction detection mechanism is not applied to units and options that
are being isolated.
• This function can be selected for the following units and options.
Tray 1, Tray 2, Tray 3, LCT, manual, Half-Fold/Tri-Fold Center Stapling, Staple and
Scanner.
• Though trouble isolation is not selected, if the specified malfunctions occur on the
above listed units or options, an alert screen appears and asks users whether to iso-
late the units or options where malfunction occurs.
See the "Trouble shooting" section for the corresponding trouble codes.
See P.486
Setting/
• The default setting is Unset for individual units and options.
Procedure
• After changing the setting, touch [Decision] and turn the main power switch OFF and
ON to make the new setting effective.
Set
10. Service Mode
"Unset"
391