Cleaning Procedure; Transfer Belt Unit; Ph Window Y,M,C,K - Konica Minolta bizhub C353 Service Manual

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

6. Other
6.4

Cleaning procedure

NOTE
• The alcohol described in the cleaning procedure represents the ethanol isopropyl
alcohol.
6.4.1

Transfer belt unit

1. Remove the transfer belt unit.
See P.43
[1]
6.4.2

PH window Y,M,C,K

1. Open the front door.
[1]
[2]
[1]
180
2. Using a cleaning pad, wipe the trans-
NOTE
• Do not wipe out with water.
• Do not wipe out with any solvents.
A02EF2C207DA
2. Remove the PH window cleaning jig
A02EF2C502DA
3. Insert the PH window cleaning jig [1]
NOTE
• Clean every PH window of Y,M,C,K.
A02EF2C503DA
Field Service Ver. 3.0 Jan. 2008
fer belt [1].
[1] from the front door.
to the cleaning port [2] and clean it
by putting the jig back and forth a
couple times.