Malfunction Code; Trouble Code (Service Call); List - Konica Minolta d-Color MF3000 PF-P08 Service Manual

Table of Contents

Advertisement

Field Service Ver. 1.1 Jun. 2010

14. MALFUNCTION CODE

14.1 Trouble code (Service Call)

• The machine's CPU performs a self-diagnostics function that, on detecting a malfunction,
gives the corresponding malfunction code on the control panel.

14.2 List

Code
Description
0010
Color PC drum motor
malfunction
0017
Main motor malfunction
0018
Developing motor
malfunction
0045
MFP board cooling fan
motor malfunction
004A
Cooling fan motor
malfunction
004E
DC power supply fan
motor malfunction
Detection timing
• The color PC drum motor does not rotate evenly even after
the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the color PC drum motor is being
rotated.
• The main motor does not rotate evenly even after the lapse
of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the main motor is being rotated.
• The developing motor does not rotate evenly even after the
lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the developing motor is being
rotated.
• The MFP board cooling fan motor does not rotate evenly
even after the lapse of a given period of time while it is
being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the MFP board cooling fan motor is
being rotated.
• The cooling fan motor does not rotate evenly even after the
lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the cooling fan motor is being
rotated.
• The DC power supply fan motor does not rotate evenly
even after the lapse of a given period of time while it is
being started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the DC power supply fan motor is
being rotated.
14. MALFUNCTION CODE
A121F4E503DA
203

Advertisement