Issue 1.0
Setting Up Alarms:
Program
Program Name
Number
90-10-01
System Alarm Setup – Alarm Type Set the alarm type 14 and 60.
90-10-02
System Alarm Setup – Report
90-24-01
System Alarm Report Notification
Time Setup – Month
90-24-02
System Alarm Report Notification
Time Setup – Day
90-24-03
System Alarm Report Notification
Time Setup – Hour
90-24-04
System Alarm Report Notification
Time Setup – Minute

Printing Reports:

Program
Program Name
Number
90-12-01
System Alarm Output – Output
Port Type
2 - 32
Description/Comments
Alarm 14 – CD-CP00-AU-LAN Link
Error (IP Layer 1)
Assign a Major or Minor alarm status
to the LAN link. This program also
assigns whether or not the alarm is
displayed to a key telephone and
whether or not the alarm information
is reported to the predefined
destination.
Alarm 60 – SIP Registration Error
Notification
Assign a Major or Minor alarm status
to the SIP Registration Error. This
program also assigns whether or not
the alarm is displayed to a key
telephone and whether or not the
alarm information is reported to the
predefined destination.
Assign whether or not the alarm is
displayed to a multiline terminal and
whether or not the alarm information
is reported to the predefined
destination in Program 90-11.
Set the month for the alarm report to
print.
Set the day for the alarm report to
print.
Set the hour for the alarm report to
print.
Set the minute for the alarm report to
print.
Description/Comments
Indicate the type of connection used
for the System Alarms. The baud
rate for the COM port should be set
in Program 10-21-02.
UNIVERGE SV8100
Assigned Data
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
(default = 0)
0 = No Report (no
autodial)
1 = Report (autodial)
(default = 0)
Month 00~12
(0 = Disabled)
(default = 00)
Day 00~31
(0 = Disabled)
(default = 00)
Day 00~23
(0 = Disabled)
(default = 00)
Day 00~59
(0 = Disabled)
(default = 00)
Assigned Data
0 = No Setting
1~3 = Reserved
4 = CTA/CTU
5 = USB Memory
(default = 0)
Alarm Reports
Level
1
2
3
Level
1
2
3

Hide quick links: