NEC Univerge SV8100 Features And Specifications Manual page 963

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
80-03-04
DTMF Tone Receiver Setup – Max.
detect level
80-03-05
DTMF Tone Receiver Setup –
Forward twist level
80-03-06
DTMF Tone Receiver Setup –
Backward twist level
80-03-07
DTMF Tone Receiver Setup – ON
detect time
80-03-08
DTMF Tone Receiver Setup – OFF
detect time
SV8100 Features and Specifications Manual
Description/Comments
Use this option to define the
maximum detection level for DTMF
Tone Receiver.
Use this option to define the forward
twist level for DTMF Tone Receiver.
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
Use this option to define the On
dectection time for DTMF Tone
Receiver.
Use this option to define the Off
dectection time for DTMF Tone
Receiver.
Assigned Data
0~15
detect level 0: 0dBm(0) to
–15dBm(15)
detect level 1:
–5dBm(0) to –20dBm(15)
detect level 2:
–10dBm(0) to –25dBm(15)
detect level 3:
–15dBm(0) to –30dBm(15)
detect level 4:
–20dBm(0) to –35dBm(15)
detect level 5:
–25dBm(0) to –40dBm(15)
detect level 6:
–30dBm(0) to –45dBm(15)
detect level 7: -35dBm(0) to
-50dBm(15)
detect level 8: -40dBm(0) to
-55dBm(15)
detect level 9: -45dBm(0) to
-60dBm(15)
detect level 10: -50dBm(0)
to -65dBm(15)
detect level 11: -55dBm(0)
to -70dBm(15)
detect level 12: -60dBm(0)
to -75dBm(15)
detect level 13: -65dBm(0)
to -80dBm(15)
detect level 14: -70dBm(0)
to -85dBm(15)
detect level 15: -75dBm(0)
to -90dBm(15)
default:
Type 1~5 = 0
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
Issue 1.0
Level
1
2
3
2 - 939