NEC Univerge SV8100 Features And Specifications Manual page 113

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
80-04-02
Call Progress Tone Detector
Setup – Min. Detection Level
80-04-03
Call Progress Tone Detector
Setup – S/N Ratio
80-04-04
Call Progress Tone Detector
Setup – No Tone Time
80-04-05
Call Progress Tone Detector
Setup – Pulse Count
80-04-06
Call Progress Tone Detector
Setup – ON Minimum Time
SV8100 Features and Specifications Manual
Description/Comments
Use this option to set the minimum
detection level.
Use this option to set the Signal to
Noise ratio.
Use this option to set No Tone
Time.
Use this option to set the Pulse
Count.
Use this option to set the minimum
On time.
Assigned Data
0~15
detect level 0:
-15dBm(0) to
-30dBm(15)
detect level 1:
-30dBm(0) to
-45dBm(15)
detect level 2:
-40dBm(0) to
-55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
0~4 (0dB ~ -20dB)
Default:
Type 1 (DT) = 4
(-20dB)
Type 2 (BT) = 4
(-20dB)
Type 3 (RBT) = 4
(-20dB)
Type 4 = 0
Type 5 = 0
0~255 (30+30-7680 ms)
default: 13 (420 ms)
Type 1 (DT) – 132
(3990 ms)
Type 2 (BT) – 132
(3990 ms)
Type 3 (RBT) – 132
(3990 ms)
Type 4, Type 5 – 0
1~255
default: 2
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255 (30+30-7680 ms)
default: 10 (330 ms)
Type 1 (DT) – 9 (300 ms)
Type 2 (BT) – 9 (300 ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
Issue 1.0