Issue 1.0
Program
Program Name
Number
21-01-10
System Options for Outgoing
Calls – Dial Digits for Toll
Restriction Path
21-01-15
System Options for Outgoing
Calls – Outgoing Disable on
Incoming Line (Toll Restriction)
21-01-16
System Options for Outgoing
Calls – Supervise Dial Detection
Timer
21-01-17
System Options for Outgoing
Calls – Restriction Digit in
Outgoing Disable on Incoming
Line
21-04-01
Toll Restriction Class for
Extensions
21-05-01
Toll Restriction Class –
International Call Restriction
Table
21-05-02
Toll Restriction Class –
International Call Permit Code
Table
2 - 270
Description/Comments
If this option is programmed with an
entry other than 0, a call does not
have a talk path unless the user
dials at least the number of digits
entered in this option when placing
an outgoing call.
This means that an entry of 4 or
higher in this program causes a
problem when dialing 000. Since it
is only a 3-digit number, the call
does not have a talk path,
preventing the emergency
dispatcher from hearing the caller.
This option should be kept at its
default setting of 0 to prevent any
problem with dialing 000. If the
system detects the call is answered,
by detecting Reversal in analog
trunks, this restores both – way
voice paths immediately.
Enable or Disable the Incoming
Line feature system wide. When
enabled applies code restriction
when hook flash is sent on inbound
trunk followed by dialed digits.
With the Outgoing Disable on
Incoming Line feature, if dial tone is
not detected after the extension
answers an incoming line, the
system determines the call is
unable to complete and releases
the DTMF receiver.
With the Outgoing Disable on
Incoming Line feature, determine
the number of digits (0~9) to be
dialed before the call should be
disconnected.
Use to assign a Toll Restriction
class to an extension for modes
1-8.
For the Toll Restriction Class you
select, Assigned (1) or Unassigned
(0) the International Call Restrict
Table (Program 21-06-01).
For the Toll Restriction Class you
select, Assign (1) or Unassign (0)
the International Call Permit Table
(Program 21-06-02).
UNIVERGE SV8100
Assigned Data
1
0~24
(default = 0)
0 = Disable
1 = Enable
(default = 1)
0~64800 (seconds)
(default = 20 seconds)
Digits 0~9
(default = 4)
Day/Night Mode
1~9 (9 = Power Failure
Mode)
1~15
(default = 2)
0 = Unassigned (No)
1 = Assigned (Yes)
default:
1, 6~15 = 0
2~5 = 1
0 = Unassigned
1 = Assigned
default:
1, 3~15 = 0
2 = 1
Code Restriction