Issue 1.0
Program
Program Name
Number
80-04-07
Call Progress Tone Detector
Setup – ON Maximum Time
80-04-08
Call Progress Tone Detector
Setup – OFF Minimum Time
80-04-09
Call Progress Tone Detector
Setup – OFF Maximum Time
Operation
None
2 - 90
Description/Comments
Use this option to set the maximum
On time.
Use this option to set the minimum
Off time.
Use this option to set the maximum
Off time.
UNIVERGE SV8100
Assigned Data
0~255 (30+30-7680ms)
default: 14 (450 ms)
Type 1 (DT) – 0
Type 2 (BT) – 20 (630 ms)
[ET]
Type 3 (RBT) – 40
1230 ms)
Type 4, Type 5 – 0
1~255 (30+30-7680ms)
default: 10 (330 ms)
Type 1 (DT) – 1 (60 ms)
Type 2 (BT) – 12 (390 ms)
Type 3 (RBT) – 83
(2520 ms)
Type 4, Type 5 – 0
0~255 (30+30-7680 ms)
default: 14 (450 ms)
Type 1 (DT) – 1 (60 ms)
Type 2 (BT) – 20 (630 ms)
Type 3 (RBT) – 115
(3480ms)
Type 4, Type 5 – 0
Automatic Release
Level
1
2
3