NEC Univerge SV8100 Features And Specifications Manual page 564

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program
Program Name
Number
24-01-06
System Options for Hold – Park
Hold Time - Normal
24-02-03
System Options for Transfer –
Delayed Call Forwarding Time
24-02-04
System Options for Transfer –
Transfer Recall Time
25-07-02
System Timers for VRS/DISA –
VRS/DISA No Answer Time
25-07-03
System Timers for VRS/DISA –
Disconnect after VRS/DISA
retransfer to IRG
25-07-07
System Timers for VRS/DISA –
Long Conversation Warning
Tone Time
25-07-08
System Timers for VRS/DISA –
Long Conversation Disconnect
Time
25-07-09
System Timers for VRS/DISA –
DISA Internal Paging Time
2 - 540
Description/Comments
Set the Park Hold Time (0~64800
seconds). A call that is parked
longer than the programmed
interval recalls the extension where
it was initially parked.
Refer to
Flexible System
Numbering on page 2-515
for
setting Flexible Timeouts for Class
of Service.
Set the Delayed Call Forwarding
interval. For an unanswered call,
Call Forward No Answer occurs
after this interval.
Set the Transfer Recall Time. An
unanswered transferred call recalls
to the extension that initially
transferred it after this interval. This
time also sets how long a
transferred call camps-on to a busy
extension.
A VRS/DISA caller can ring an
extension for this time before the
system sets the call as a Ring No
Answer. After this time expires, the
call follows the programmed Ring
No Answer routing (set in Program
25-03 and Program 25-04).
Define the system timers which
affect DID and DISA after VRS/
DISA retransfer to IRG.
Determine the time a DISA caller or
any trunk-to-trunk (such as Tandem
Trunking) conversation can talk
before the Long Conversation tone
is heard.
This time determines how long the
system waits before disconnecting
a DISA caller or any trunk-to-trunk
(such as Tandem Trunking)
conversation call after the Long
Conversation tone is heard.
This is the maximum length of an
Internal Page placed by a DISA
caller. If the Page continues longer
than this time, the system
terminates the DISA call.
UNIVERGE SV8100
Assigned Data
1
0~64800 (seconds)
(default = 90 seconds)
0~64800 (seconds)
(default = 10)
0~64800 (seconds)
(default = 30)
0~64800 (seconds)
(default = 0 seconds)
0~64800 (seconds)
(default = 60 seconds)
0~64800 (seconds)
(default = 1800
seconds)
0~64800 (seconds)
(default = 30 seconds)
0~64800 (seconds)
(default = 30 seconds)
Flexible Timeouts