bizhub C350 Field Service Ver.1.0 Mar. 2004
1.3.10

Stapler Phase Adjustment

[1]
[4]
[4]
[8]
[10]
[7]
[12]
[11]
[16]
• Make phase adjustment of the Stapler
following the procedures given below
whenever the Gear or Timing Belt in
front of the Stapler has been replaced
or removed for some reason, since
such replacement or removal will
cause mistiming between the staple
driving by the Staple Driver (the lower
4583fs2504c0
unit of the Stapler) and the staple
clinching by the Staple Clincher (the
upper unit of the Stapler).
1. Remove the Stapler.
[3]
☞ 2-6
2. Remove the E-Ring [1], and remove
[4]
3. Remove the Jam Release Dial 2 [3].
[2]
4. Remove the three screws [4], and
[5]
4583fs2543c0
5. Remove the Gear Cover [7] from the
[9]
6. Remove the E-Ring [8], and remove
[6]
4583fs2505c0
7. Remove two E-Rings [11], and
[13]
[14]
8. Remove the spacer and the spring
[15]
[17]
9. Remove the screw [15] and the
4583fs2506c0
2-7
the Jam Release Dial 1[2].
remove the Stapler Front Cover [5].
Staple Driver [6].
the Side Cover [10] from the Staple
Clincher [9].
remove the Staple Jam Release
Gear [12], the Timing Belt [13] and
the Middle Gear 1 [14].
located behind the Staple Jam
Release Gear.
spring [16], and remove the Belt Ten-
sion Roller [17].