Field Service Ver. 2.0 Jan. 2008
6.3

Stapler phase adjustment

6.3.1

Adjustment procedure

1. Remove the stapler.
See P.14
1
[1]
[2]
[4]
[4]
1
[3]
[5]
[2]
A0D6F3C514DA
[3]
[4]
[5]
A0D6F3C515DB
[4]
[1]
A0D6F3C516DB
6. Mechanical adjustment
• Make phase adjustment of the stapler
following the procedures given below
whenever the gear or timing belt in
front of the stapler has been replaced
or removed for some reason, since
such replacement or removal will
cause mistiming between the staple
driving by the staple driver (the lower
unit of the stapler) and the staple
clinching by the staple clincher (the
upper unit of the stapler).
2. Remove the E-ring [1], and remove
the jam release dial 1 [2].
3. Remove the jam release dial 2 [3].
4. Remove the three screws [4], and
remove the stapler front cover [5].
5. Remove the gear cover [2] from the
staple driver [1].
6. Remove the E-ring [3], and remove
the side cover [5] from the staple
clincher [4].