Original Glass/Ir Front Cover; Control Panel - Konica Minolta Bizhub C350 Service Manual

Includes: standard controller df-601 pc-101/pc-201 pc-401 ad-501 fs-501
Hide thumbs Also See for Bizhub C350:
Table of Contents

Advertisement

Other
4.3.6

Original Glass/IR Front Cover

[5]
[4]
1. Remove the IR Upper Right Cover.
☞ 2-43
2. Remove each Screw [1], and remove the Original Glass fixing bracket (near side/
inmost side) [2].
3. Remove the Original Glass [3].
4. Remove the IR Right Cover and IR Upper Front Cover.
☞ 2-40, 2-43
5. Remove the IR Left Cover.
☞ 2-41
6. Remove five Screws [4], and remove the IR Front Cover [5].
4.3.7

Control Panel

[1]
bizhub C350 Field Service Ver. 2.0 April 2004
[4]
[2]
[1]
4036fs2160c0
2-44
[3]
[1]
1. Remove four caps [1] at both ends of
Control Panel.
[2]
4036fs2159c2

Hide quick links: