Trouble code
Code
Item
C0BA0
Elevator Motor (M7-FN) drive
malfunctions
2.2.1

How to reset

• Press the Trouble Reset Switch on the Tech. Rep. Setting Switches Board to reset the
following malfunctions: scanner-related malfunctions, fusing-related malfunctions, expo-
sure lamp-related malfunctions and C3FFF.
• For any other malfunctions, open and close the Front Door or turn OFF and ON the
Power Switch.
bizhub C350 Field Service Ver.1.0 Mar. 2004
Description
• The Elevator Tray Upper Limit Sensor PQ (PWB-D FN)
is not activated even after the lapse of a given period of
time after M7-FN has been energized (to start raising
the Elevator Tray).
• The Elevator Tray Upper Limit Switch (S2-FN) or Eleva-
tor Tray Lower Limit Switch (S3-FN) is actuated after
M7-FN has been energized.
4-8