bizhub C350 Field Service Ver.1.0 Mar. 2004
1.4.4

Transport Tray section misfeed

A. Detection timing
Type
Misfeed due to
paper not reached
Misfeed is detected if the Exit Sensor (PC6-DF) is not turned ON within a preset
the Exit Sensor
time after exit operation started in the 1-Sided Mode.
(in the 1-Sided
Mode)
Misfeed is detected if the difference between the paper feeding size measured at
Misfeed at the
the Turnover Sensor (PC5-DF) and that measured at the Exit Sensor (PC6-DF) is
Transport Tray
20 mm or more.
B. Action
Turnover Sensor (PC5-DF)
Exit Sensor (PC6-DF)
Step
1
Initial check items
2
PC5-DF I/O, sensor check
3
PC6-DF I/O, sensor check
4
PWB-A DF replacement
NOTE
• Each sensor is automatically adjusted when the Power Switch is turned ON as
special means for detecting a paper misfeed. If a sensor adjustment error occurs
through this procedure, a misfeed is detected as paper remaining misfeed at the
corresponding sensor.
Relevant electrical parts
Action
4-5
Description
Control Board (PWB-A DF)
WIRING DIAGRAM
Control signal
-
PWB-A DF CN9A DF-3
PWB-A DF CN9A DF-6
-
Jam Display
Location
(Electrical compo-
nents)
-
G-2
H-2
E-5