Writing Into The Compact Flash - Konica Minolta Bizhub C350 Service Manual

Includes: standard controller df-601 pc-101/pc-201 pc-401 ad-501 fs-501
Hide thumbs Also See for Bizhub C350:
Table of Contents

Advertisement

bizhub C350 Field Service Ver.1.0 Mar. 2004
2.1.4

Writing into the Compact flash

1. Put the data of Firmware in the optional directory.
(C:\TSS2 in the below figure)
NOTE
• The file name of Firmware data consists of the "Release
Date_Version_CHECKSUM-****.exe".
2. Double-click the Firmware data, and specify the directory to be uncompressed, and
then uncompress it.
NOTE
• When old Firmware is still left in the specified directory to be uncompressed,
delete it before uncompressing.
3. Mount the Compact flash on the PC, and check the Drive name, which was recognized
in the Windows.
(F-Drive in the following figure)
4. Click "Start"→"Program"→"Accessories"→"Command prompt" to open the Command
prompt.
5. Use the Command prompt to move into the uncompressed directory.
2-3
Firmware rewriting
4036fs2622e0