Konica Minolta Bizhub C350 Service Manual page 264

Includes: standard controller df-601 pc-101/pc-201 pc-401 ad-501 fs-501
Hide thumbs Also See for Bizhub C350:
Table of Contents

Advertisement

Malfunction code
Code
Item
C0B00 Finishing option transport system
malfunction
C0B05 Finishing option Paddle Motor mal-
function
C0B20 Finishing option Stapler Unit CD
drive failure
C0B25 Finishing option Stapler Unit Slide
Motor malfunction
C0B30 Finishing option Aligning Bar mov-
ing mechanism malfunction
C0B39 Finishing option Front Aligning
Motor malfunction
C0B3A Finishing option Rear Aligning
Motor malfunction
C0B48 Finishing option Exit Roller pres-
sure/retraction failure
C0B4A Finishing option Storage Roller
pressure/retraction failure
C0B4C Finishing option Exit Motor mal-
function
C0B50 Finishing option stapling mecha-
nism malfunction 1
C0B55 Finishing option Staple/Folding
Motor malfunction
C0B75 Finishing option Punch Cam Motor
drive failure
C0B76 Finishing option Punch Unit Board
malfunction
C0B77 Finishing option Punch Side Regis-
tration Motor malfunction
C0B78 Finishing option Punch Motor mal-
function
C0B79 Finishing option Punch Sensor
malfunction
C0B80 Finishing option Shift Motor mecha-
nism malfunction
C0BA0 Finishing option Elevator drive mal-
function
C0BF1 Finishing option Backup RAM fail-
ure
C0F30 Abnormally low toner density
detected Cyan ATDC Sensor
C0F31 Abnormally high toner density
detected Cyan ATDC Sensor
C0F32 Abnormally low toner density
detected Magenta ATDC Sensor
bizhub C350 Field Service Ver. 2.0 April 2004
Description
☞ See FS-501 or FS-601 Service Manual.
• T/C 0.21 % or less is detected ten consecutive times
in the Developing Unit as validated through the toner
replenishing amount determination control.
• T/C 15.5 % or more is detected ten consecutive times
in the Developing Unit as validated through the toner
replenishing amount determination control.
• T/C 0.21 % or less is detected ten consecutive times
in the Developing Unit as validated through the toner
replenishing amount determination control.
4-22