bizhub C350 Field Service Ver. 2.0 April 2004
7.2.1

Initialize Procedure

1. Turn OFF the Power Switch.
2. With the circuit across pins of PJ2 closed, turn ON the Power Switch.
3. In about 5 sec., open the PJ2 circuit.
4. Check that the message "Initialize Completed" is displayed on the Touch Panel and
then touch "END."
7.2.2

Memory Clear Procedure

• For details, see Security manual
7.2.3

If the machine exhibits an erratic display or operation.

1. Turn OFF and ON the Power Switch.
1. Unplug and plug in the power cord.
2. Initialize the machine.
3. Memory Clear the machine.
• Do not perform Memory Clear casually, as it clears the types of data mentioned
above. If Memory Clear has been performed, be sure to make settings for the func-
tions that have been cleared once again.
7.2.4

Data/Conditions Cleared by Reset Switches/Pins

Clearing Method
Data Cleared
Misfeed display
Fusing
Optical
Malfunction
Scanner
display
C3FFX
Others
Erratic operation/display
Utility Mode
(Store, User's Choice:1, 2, Admin. Code)
Tech. Rep. Mode
(System Input)
Security Mode
(Counter Setting)
Touch Panel Correction Mode
❍: Cleared
—: Not cleared
Front Door
Trouble
Open/Close
Reset Switch
3-105
Board switch
Memory
Initialize
Clear