Tech. Rep. Mode; Tech. Rep. Mode Function Setting Procedure - Konica Minolta Bizhub C350 Service Manual

Includes: standard controller df-601 pc-101/pc-201 pc-401 ad-501 fs-501
Hide thumbs Also See for Bizhub C350:
Table of Contents

Advertisement

bizhub C350 Field Service Ver. 2.0 April 2004
4.

TECH. REP. MODE

4.1

Tech. Rep. Mode function setting procedure

NOTE
• Ensure appropriate security for Tech. Rep. mode function setting procedures.
They should NEVER be shown to any unauthorized person not involved with ser-
vice jobs.
A. Procedure
1. Press the Utility key.
2. Touch "Counter List."
3. Press the following keys in this order.
Stop
0
0
4. Enter the 8-digit service code and touch "Enter." (The default value is "00000000.")
NOTES
• The service code entered is displayed as "
• If a wrong service code is entered, touch "Enter" to go back to the Basic screen.
• When access is attempted a fourth time after a wrong service code has been
entered three times, the "Enter" will not be displayed. In this case, the Power
Switch must be turned OFF and ON.
• When the access to the Tech. Rep. mode is successfully made with the correct
service code entered, the machine clears the count of illegal access to the Tech.
Rep. mode.
5. The Tech. Rep. Mode menu will appear.
NOTES
• Be sure to change the service code from its default value.
• For the procedure to change the service code, see the Security Mode.
B. Exiting
• Touch the "Fin. Time" key.
C. Changing the Setting Value in Tech. Rep. Mode Functions
• Use the ID key to change the + sign to - sign, or vice versa.
• Use the Up/Down key to enter or change the setting value.
• Use the 10-Key Pad to enter the setting value. (To change the setting value, first press
the Clear key before making an entry.)
Stop
0
1
3-39
."
TECH. REP. MODE
4036fs3034e0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents