5.
Configure the backup virtual server.
Alteon Web switch # 1 will act as a backup for virtual server 10.10.10.2. Both virtual servers in
this example are configured with the same real server group and provide identical services.
>> Virtual server 2 http service # /cfg/slb/virt 2 (Select menu for virtual server 2)
>> Virtual server 1 # vip 10.10.10.2
>> Virtual server 1 # ena
>> Virtual server 1 # service http
>> Virtual server 1 # group 1
6.
Configure IP interfaces for each network that will be attached to OSPF areas.
>> Virtual server 1 # /cfg/ip/if 1
>> IP Interface 1 # addr 10.10.7.1
>> IP Interface 1 # enable
>>
IP Interface 1 # ../if 2
>> IP Interface 2 # addr 10.10.10.40
>> IP Interface 2 # enable
7.
Enable OSPF on Web switch 1.
>> IP Interface 2 # ../ospf/on
8.
Define the backbone.
>> Open Shortest Path First # aindex 0
>> OSPF Area (index) 0 # areaid 0.0.0.0
>> OSPF Area (index) 0 # type transit
>> OSPF Area (index) 0 # enable
9.
Define the stub area.
>> OSPF Area (index) 0 # ../aindex 1
>> OSPF Area (index) 1 # areaid 0.0.0.1
>> OSPF Area (index) 1 # type stub
>> OSPF Area (index) 1 # enable
n
94
Chapter 4: OSPF
(Set the IP address for virtual server 2)
(Enable the virtual server)
(Select menu for service on virtual server)
(Use real server group 1 for http service)
(Select menu for IP interface 1)
(Set IP address on backbone network)
(Enable IP interface 1)
(Select menu for IP interface 2)
(Set IP address on stub area network)
(Enable IP interface 2)
(Enable OSPF on Web switch 1)
(Select menu for area index 0)
(Set the ID for backbone area 0)
(Define backbone as transit type)
(Enable the area)
(Select menu for area index 1)
(Set the ID for stub area 1)
(Define area as stub type)
(Enable the area)