Positioning the 200i server on the switch shelf

Introduction
On an Option 11C, the 200i server cannot be placed in slots 11 or 12 (marked
MM2 and MM3).
Note: The 200i server can be placed in slot 10 (marked MM1) only if the 200i
server is NTRH14AA Release 12 or later. (The release is identified on the sticker
located below the RS-232 maintenance port on the 200i server faceplate.)
The 200i server physically occupies two slots. However, for the purposes of
connectivity, the 200i server is considered to be in the first slot.
To position the 200i server on the switch shelf
1
Ensure that no cables are connected to the slot in which you are installing
the 200i server.
2
Open the lock latches at the top and bottom of the 200i server faceplate.
3
Slide the 200i server into an unoccupied slot. At this time, do not push the
200i server into place against the backplane. If you do, the server powers
up, and it should not be powered up at this time.
Note: The 200i server requires two consecutive unoccupied slots on the
shelf. Ensure that the 200i server is positioned correctly between the
parallel slots.
4
Connect the intermediate SCSI cable.
Note: See
5
Connect the peripheral devices.
Note: See
Part 2: 200i Server Hardware Installation
Installing the server, cables, and peripheral devices
"Connecting the intermediate SCSI cable" on page
"Connecting peripheral devices to the 200i server" on page
50.
67.
49