Serial Port Settings

This window allows the user to adjust the Baud Rate and the Auto Logout values.
To view the following window, click System Configuration > Serial Port Settings, as show below:
The fields that can be configured are described below:
Parameter
Description
Specify the baud rate for the serial port on the Switch. There are four possible baud rates to
Baud Rate
choose from, 9600, 19200, 38400 and 115200. For a connection to the Switch using the
console port, the baud rate must be set to 115200, which is the default setting.
Select the logout time used for the console interface. This automatically logs the user out
Auto Logout
after an idle period of time, as defined. Choose from the following options: 2, 5, 10, 15
minutes or Never. The default setting is 10 minutes.
Display the data bits used for the serial port connection.
Data Bits
Display the parity bits used for the serial port connection.
Parity Bits
Display the stop bits used for the serial port connection.
Stop Bits
Click the Apply button to implement changes made.

Warning Temperature Settings

This window allows the user to configure the system warning temperature parameters.
To view the following window, click System Configuration > Warning Temperature Settings, as show below:
The fields that can be configured are described below:
Parameter
Description
Use the drop-down menu to enable or disable the traps state option of the warning
Traps State
temperature setting.
Use the drop-down menu to enable or disable the log state option of the warning
Log State
temperature setting.
Enter the high threshold value of the warning temperature setting.
High Threshold
Figure 2-10 Serial Port Settings window
Figure 2-11 Warning Temperature Settings window