Setting The Transmit Hold Multiplier Value; Setting The Transmit Delay; Setting The Reinit Delay; Setting The Notification Interval - Alcatel-Lucent OmniSwitch 6850-48 Network Configuration Manual

Software release 6
Hide thumbs Also See for OmniSwitch 6850-48:
Table of Contents

Advertisement

Configuring 802.1AB

Setting the Transmit Hold Multiplier Value

To set the transmit hold multiplier value, enter the
ple, to set the transmit hold multiplier value to 2, enter:
-> lldp transmit hold-multiplier 2
Note: The Time To Live is a multiple of the transmit interval and transmit hold-multiplier.

Setting the Transmit Delay

To set the minimum time interval between successive LLDPDUs transmitted, enter the
delay
command. For example, to set the transmit delay value to 20 seconds, enter:
-> lldp transmit delay 20
By default, the transmit delay is less than or equal to the multiplication of the transmit interval and 0.25.

Setting the Reinit Delay

To set the time interval that must elapse before the current status of a port is reinitialized after a status
change, enter the
lldp reinit delay
-> lldp reinit delay 7

Setting the Notification Interval

To set the time interval that must elapse before a notification about the local system Management Informa-
tion Base (MIB) change is generated, enter the
the notification value to 130 seconds, enter:
-> lldp notification interval 130
Note: In a specified interval, generating more than one notification-event is not possible.
OmniSwitch AOS Release 6 Network Configuration Guide
lldp transmit hold-multiplier
command. For example, to set the reinit delay to 7 seconds, enter:
lldp notification interval
September 2009
Configuring 802.1AB
command. For exam-
lldp transmit
command. For example, to set
page 19-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents