Setting Ethernet Parameters for Non-Combo Ports

Setting Ethernet Parameters for Non-Combo Ports
The following sections describe how to use CLI commands to configure non-combo ports. (See the tables
in
"Valid Port Settings on OmniSwitch 6400 Series Switches" on page
OmniSwitch 6850 Series Switches" on page
Switches" on page
1-7, and
more information.)
While you can use the CLI commands described in the following sections to configure combo ports, please
keep in mind that configuration changes made on combo ports configured as either forced fiber or
preferred fiber will only be made on the SFP fiber connectors and not to the copper
RJ-45 10/100/1000 ports.
Similarly, configuration changes made on combo ports configured as either forced copper or preferred
copper, will only be made on the copper RJ-45 10/100/1000 ports and not to the SFP fiber connector. See
"Setting Ethernet Combo Port Parameters" on page 1-21

Setting Interface Line Speed

The
interfaces speed
on an entire switch (slot) to one of the following parameter values:
10 (10 Mbps Ethernet)
100 (100 Mbps Fast Ethernet)
1000 (1000 Mbps Gigabit Ethernet)
10000 (10000 Mbps Gigabit Ethernet)
auto (auto-sensing, which is the default)—The auto setting automatically detects and matches the line
speed of the attached device.
Note that available settings for the interfaces speed command depend on the available line speeds of your
hardware interface. See
Port Settings on OmniSwitch 6850 Series Switches" on page
6855 Series Switches" on page
page 1-7
for more information.
In order to set up a speed and duplex on a port, autonegotiation should be disabled.
-> interfaces 2 autoneg disable
To set the line speed on an entire switch, enter interfaces followed by the slot number and the desired
speed. For example, to set slot 2 to 100 Mbps, enter:
-> interfaces 2 speed 100
To set the line speed on a single port, enter interfaces followed by the slot number, a slash (/), the port
number, and the desired speed. For example, to set the line speed on slot 2 port 3 at 100 Mbps, enter:
-> interfaces 2/3 speed 100
To set the line speed on a range of ports, enter interfaces followed by the slot number, a slash (/), the first
port number, a hyphen (-), the last port number, and the desired speed. For example, to set the line speed
on ports 1 through 3 on slot 2 at 100 Mbps, enter:
page 1-16
1-6,
"Valid Port Settings on OmniSwitch 9000 Series Switches" on page 1-7
command is used to set the line speed on a specific port, a range of ports, or all ports
"Valid Port Settings on OmniSwitch 6400 Series Switches" on page
1-7, or
"Valid Port Settings on OmniSwitch 9000 Series Switches" on
OmniSwitch AOS Release 6 Network Configuration Guide
1-5,
"Valid Port Settings on OmniSwitch 6855 Series
or more information on configuring combo ports.
1-6,
"Valid Port Settings on OmniSwitch
Configuring Ethernet Ports
"Valid Port Settings on
1-5,
"Valid
September 2009
for

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents