Configuring VLAN Stacking
10
Create a SAP profile on PE1 and PE2 that will map the inner CVLAN tag 802.1p value to the outer
SVLAN tag using the
-> ethernet-service sap-profile map_pbit priority map-inner-to-outer-p
11
Associate the "map_pbit" profile to SAP 30 using the
This profile will only apply to Customer B traffic, so it is not necessary to associate the profile with SAP
20.
-> ethernet-service sap 30 sap-profile map_pbit
12
Verify the VLAN Stacking service configuration using the
-> show ethernet-service
Service Name : CustomerA
SVLAN
: 100
NNI(s)
: 3/1
SAP Id
: 20
UNIs
CVLAN(s)
sap-profile : default-sap-profile
Service Name : CustomerB
SVLAN
: 200
NNI(s)
: 3/1
SAP Id
: 10
UNIs
CVLAN(s)
sap-profile : map_pbit
The following is an example of what the sample configuration commands look like entered sequentially
on the command line of the provider edge switches:
-> ethernet-service svlan 100
-> ethernet-service service-name CustomerA svlan 100
-> ethernet-service svlan 100 nni 3/1
-> ethernet-service sap 20 service-name CustomerA
-> ethernet-service sap 20 uni 1/1
-> ethernet-service sap 20 cvlan all
-> ethernet-service svlan 200
-> ethernet-service service-name CustomerB svlan 200
-> ethernet-service svlan 200 nni 3/1
-> ethernet-service sap 30 service-name CustomerB
-> ethernet-service sap 30 uni 2/1
-> ethernet-service sap 30 cvlan 10
-> ethernet-service sap-profile map_pbit priority map-inner-to-outer-p
-> ethernet-service sap 30 sap-profile map_pbit
OmniSwitch AOS Release 6 Network Configuration Guide
ethernet-service sap-profile
: 1/1
: all
: 2/1
: 10
VLAN Stacking Application Example
command.
ethernet-service sap sap-profile
show ethernet-service