6.4

MMST_InterruptParameter Structure

The following are the interrupt parameter structures used by interrupt parameter settings.
Variable name
IntCondition
IntSensitivity
IntOutputDataSetting
IntTimeSetting
IntJudgeValue1
IntJudgeValue2
IntTime
6.5

MMST_InterruptData Structure

The following are the interrupt data structures used by interrupt callback functions.
Variable name
BoardID
FreerunningTime
IntFactor[2]
IntFactorDetail[64]
6.6

MMST_CamPositionData Structure

The following are the cam position calculation data structures used by cam position calculation functions.
Variable name
CamNo
Stroke
LengthPerCycle
ReferencePosition
CommandPositionPerCycle
CommandPosition
6.7

MMST_RotaryCutterCamData Structure

The following are the auto-generation data structures used by cam auto-generation (rotary cutter cam(central reference)).
Variable name
Resolution
AutoGenerationOption
SyncSectionAccelerationRatio
SheetLength
SheetSyncWidth
SyncAxisLength
SyncPositionAdjustment
AccelerationDecelerationWidth
NumberOfCutter
Data type
Name
unsigned long
Interrupt condition
unsigned long
Interrupt detection timing
unsigned long
Factor details output setting
unsigned long
Condition for condition completion continue
unsigned long
Interrupt condition judge value 1
unsigned long
Interrupt condition judge value 2
unsigned short
Time for condition completion [ms]
Data type
Name
unsigned long
Board ID (0 to 3)
unsigned short
Free-running timer
unsigned long
[Md.1101] Interrupt factor (1 to 64)
unsigned long
[Md.1102] Interrupt factor details
Data type
Name
unsigned short
[Cd.613] Cam position calculation: Cam No.
long
[Cd.614] Cam position calculation: Stroke amount
unsigned long
[Cd.615] Cam position calculation: Cam axis length per cycle
long
[Cd.616] Cam position calculation: Cam reference position
unsigned long
[Cd.617] Cam position calculation: Cam axis current value per cycle
long
[Cd.618] Cam position calculation: Cam axis feed current value
Data type
Name
unsigned long
[Cd.611] Cam auto-generation data
unsigned short
short
unsigned long
unsigned long
unsigned long
long
unsigned long
unsigned short
Resolution
Auto-generation option
Synchronous section acceleration ratio
Sheet length
Sheet synchronization width
Synchronous axis length
Synchronous position adjustment
Acceleration/deceleration width
Number of cutter
6 STRUCTURE LIST