Mitsubishi MR-EM340GF User Manual page 204

Simple motion board
Table of Contents

Advertisement

Value
Constant definition
1203H
MMERR_FB_START_NOT_POSSIBLE
1204H
MMERR_FB_AXIS_STOPPED
1205H
MMERR_FB_READ_OR_WRITE_PARAMETER
1206H
MMERR_FB_INSTRUCTION_RUNNING
1207H
MMERR_FB_LINK_DEVICE_INACCESSIBLE
1300H
MMERR_FB_WARNING
7 ERROR CODE LIST
202
7.6 Function Block Related Errors
Occurrence cause/Remedy
Positioning can not be started. Execute the function block again after the
control in execution is completed or turning OFF the start signal.
The axis is in a Stopping state, or the stop command for the axis is ON. Execute
the function block again after changing the axis status to Standstill or turning
OFF the stop command.
Reading or writing the parameter failed. Check if the parameter No. or object
index is correct or the setting data is within the range.
Another function block is executing the instruction code. Check the completion
of the function block executing the instruction code, and then execute the target
function block.
Access to the link devices is disabled. Turn OFF the link device use flag
(LinkDeviceUse) of the AXIS_REF class, and execute the target function block.
A warning occurred.

Advertisement