Area Parameters - Bosch D9412GV4 Program Entry Manual

Table of Contents

Advertisement

D9412GV4/D7412GV4/D7212GV4
3.10

Area Parameters

This programming module contains three programming categories: Area Parameters, Bell
Parameters, and Open/Close Options.
3.10.1
Area Parameters
Enter the area number you are programming.
Area# Area On
Default:
Selection:
Yes
No
Use this program item to enable or disable the area specified.
Refer to Section Keypad Programming of Area # On and Area# Account Number, page 61.
NOTICE!
Area 1 must be enabled:
NOTICE!
To meet UL 864 requirements (D9412GV4 and D7412GV4), set A# Area On to Yes.
Area# Account Number
Default:
Selection:
Determines the account number for this area. An account number must be assigned to each
active area.
Account numbers are used to group areas together. Each area can have a different account
number, or several areas can share the same account number. The control panel uses the
account number as a reference for arming and keypad text displays.
Contact ID: Only the last four digits are sent.
Modem IIIa
Keypad Programming of Area # On and Area# Account Number
D1255
1.
2.
3.
4.
Bosch Security Systems, Inc.
Yes (Area 1 only)
Yes or No
Enable area
Disable area
System events such as power and phone supervision do not send a report correctly if
Area 1 is disabled.
When programmed No, points assigned to this area do not generate events, show at the
keypad when arming and disarming, or send status reports. All user authority in this area
is turned off while the area is disabled.
0000
For Modem format and Contact ID (four-digit account numbers): 0000
to 9999, BBBB to FFFF
For Modem format (ten-digit account numbers): 0000000000 to
9999999999, BBBBBBBBBB to FFFFFFFFFF
2
: Enter a four-digit or ten-digit number.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the AREA PARAMETERS option. Press [ENT].
The keypad reads AREA NUM 1 – 32 (1 – 8 for the D7412GV4).
Enter the area number you wish to configure and press [ENT]. The current area status
shows (for example, AREA 1 ON: YES).
Press [ENT] to change the area's status.
Program Entry Guide
Panel and Area Wide Parameters | en
F.01U.218.312 | 04 | 2012.03
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv4D7212gv4

Table of Contents