D9412GV4/D7412GV4/D7212GV4
Determines whether this keypad sounds a tone and displays the PLEASE CLOSE NOW
warning on the keypad when a Closing Window activates, indicating the area automatically
arms soon.
CC# Close Door Warning Tone
Default:
Selection:
Yes
No
This feature is not available with the D7212GV4. Keep the default setting.
Determines whether this keypad sounds an audible tone and displays the CLOSE DOOR #
warning on the keypad. This occurs when the door is physically held open past the shunt time
and the extend time has a value greater than zero for the door assigned to this area in CC#
Assign Door.
CC# Scroll Lock
Default:
Selection:
Yes
No
Use this parameter to enable a special non-scrolling option for the idle system status display
text on a keypad. This keypad mode requires the user to press the [PREV] or [NEXT] key on
the keypad to unlock the display and begin scrolling through the system status displays.
CC# Menu Key Lock
Default:
Selection:
Yes
No
Determines if the Menu Key, when pressed, requires a passcode to access the functions.
NOTICE!
If this parameter is set to Yes, users must enter a passcode after pressing the Menu key. When
the passcode is validated, only those functions for which the user has authority appear in the
list. If a function in the Menu List is passcode protected, the user does not need to enter the
passcode again.
CC# Abort Display
Default:
Selection:
Yes
No
For SIA CP-01 Compliance
Bosch Security Systems, Inc.
Yes
Yes or No
This keypad sounds a tone and displays CLOSE DOOR #.
This keypad does not sound the tone or activate the display..
No
Yes or No
Prevents the idle system status text from scrolling automatically.
Requires user intervention to advance.
Allows the idle system status text to scroll automatically without user
intervention.
No
Yes or No
If set to Yes, the user is prompted to enter a passcode after pressing
the Menu key on the keypad. The items programmed in the Menu List
for this specific keypad are filtered by the user's authority level. Only
those items in the menu list for which the user has authority appear.
If set to No, when the user presses the Menu key, all items that are
programmed in the Menu List for the Command Center Address
(Keypad Address) appear, regardless of the user's authority level.
Yes
Yes or No
This keypad shows the Alarm Aborted message for all aborted alarms
within its scope.
This keypad does not show the Alarm Aborted message for all aborted
alarms within its scope.