D9412GV4/D7412GV4/D7212GV4
Phone 2
Phone 3
Phone 4
SDI 88 Path 1
SDI 88 Path 2
SDI 88 Path 3
SDI 88 Path 4
SDI 92 Path 1
SDI 92 Path 2
SDI 92 Path 3
SDI 92 Path 4
SDI2-1 Path 1
SDI2-1 Path 2
SDI2-1 Path 3
SDI2-1 Path 4
SDI2-2 Path 1
SDI2-2 Path 2
SDI2-2 Path 3
SDI2-2 Path 4
NOTICE!
To meet UL 864 requirements for Central Station and Remote Station applications (D9412GV4
and D7412GV4), program a Primary Device.
Select the communication device and the primary destination.
Refer to Section 3.4 Programming Path Numbers and Network Addresses for Enhanced
Communications, page 40 to enable enhanced communication paths.
Keypad Programming of R# Primary Device
D1255
1.
2.
3.
4.
When the keypad reads PARAMETER SAVED, your selection has been configured.
D1260
1.
2.
3.
4.
When the keypad reads Parameter Saved, your selection has been configured.
Bosch Security Systems, Inc.
Phone 2 is this group's primary destination.
Phone 3 is this group's primary destination.
Phone 4 is this group's primary destination.
Path 1 on SDI 88 is this group's primary destination.
Path 2 on SDI 88 is this group's primary destination.
Path 3 on SDI 88 is this group's primary destination.
Path 4 on SDI 88 is this group's primary destination.
Path 1 on SDI 92 is this group's primary destination.
Path 2 on SDI 92 is this group's primary destination.
Path 3 on SDI 92 is this group's primary destination.
Path 4 on SDI 92 is this group's primary destination.
Path 1 on SDI2-1 is this group's primary destination.
Path 2 on SDI2-1 is this group's primary destination.
Path 3 on SDI2-1 is this group's primary destination.
Path 4 on SDI2-1 is this group's primary destination.
Path 1 on SDI2-2 is this group's primary destination.
Path 2 on SDI2-2 is this group's primary destination.
Path 3 on SDI2-2 is this group's primary destination.
Path 4 on SDI2-2 is this group's primary destination.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the ROUTE GRP 1 - 4 option.
At the ROUTE GRP 1 - 4 prompt, enter the route group number you wish to configure and
press [ENT]. The keypad reads RT GRP 1 PRIMARY, and then the current configuration
(for example, SDI 88 PATH 4).
To change the configuration, press [ENT] when the current configuration shows, and
then press [NEXT] or [PREV] to scroll through the options, as listed in Section R# Primary
Device, page 30.
When the keypad reads the desired configuration option, press [ENT] to select it.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the Route Group 1 - 4 option.
At the Route Group 1 - 4 prompt, enter the route group number you wish to configure
and press [ENTER]. The keypad reads Rt Group 1 Primary, and then the current
configuration (for example, SDI 88 PATH 4).
To change the configuration, press the Edit softkey, and then press the Next or the
Previous softkey to scroll through the options, as listed in Section R# Primary Device,
page 30.
When the keypad reads the desired configuration option, press the Save softkey to select
it.
Program Entry Guide
Panel and Area Wide Parameters | en
F.01U.218.312 | 04 | 2012.03
31