en | Panel and Area Wide Parameters
A# Disable O/C in Window
Default:
Selection:
Yes
No
Determines if opening and closing activity is reported when it occurs inside an Opening or
Closing Window, as programmed in O/C Windows.
Reports are always logged and printed on a local printer, if installed.
A# Auto Close
Default:
Selection:
Yes
No
With this program item, the control panel can automatically master arm the area at the end of
the Closing Window regardless of the previous armed state.
NOTICE!
When an area master arms automatically at the end of a Close window, the system disregards
the settings in A# Force Arm Max and P## Bypassable for any faulted points. The faulted
points arm when they return to normal state.
A# Fail to Open
Default:
Selection:
Yes
No
Use to determine if a Fail to Open Report is sent for this area. This can determine if a user
failed to disarm the area before the Opening Window expiring. Normal Opening and Closing
Reports do not need to be programmed to use this feature.
F.01U.218.312 | 04 | 2012.03
Yes
Yes or No
Do not send Opening and Closing Reports to the central station if they
occur inside an active window.
If an Opening or Closing Report occurs outside a window, send it with
an early or late modifier. Refer to Section 6.1.1 Opening and Closing,
page 154.
The active window must be a Closing Window for Closing Reports. It
must be an Opening Window for Opening Reports.
Send Opening and Closing Reports to the central station even when
they occur inside a programmed window. If an opening or closing
occurs outside of the appropriate window, it reports but does not have
an early or late modifier.
If you want to monitor all opening and closing activity and use features
provided by Opening and Closing Windows, program this item as No,
and program the appropriate O/C Windows.
No
Yes or No
The area automatically master arms at the end of the Close Window.
When the area is armed automatically, a Closing Report is sent if the
Area or Account Reports are programmed to do so.
Do not automatically arm the area at the end of the Close Window.
No
Yes or No
Fail to Open Report is sent for this area if the area was not disarmed
when the Opening Window stop time occurred.
Fail to Open Report is not sent for this area.