84
en | Panel and Area Wide Parameters
Cycle Relay
Auto Re-arm
For SIA CP-01 Compliance
CC# Passcode Enter Function must be left at its default value Arm/Disarm.
CC# Dual Authentication (D9412GV4/D7412GV4 Only)
This parameter enables or disables the Dual Authentication feature. With Dual Authentication,
a user must enter a passcode AND present a credential to a card reader to gain access
through a door.
NOTICE!
Users cannot use a key fob as the second method of authentication when Dual Authentication
is enabled.
NOTICE!
Dual Authentication applies to CC## Passcode Enter Function settings of Arm/Disarm, Arm
Cycle Relay, Cycle Door, and Auto Re-arm. When Dual Authentication is enabled, user
commands (for example, CMD 43), require a passcode only.
Enabling Dual Authentication:
If any of these conditions are not met, then the Passcode Function operates with single
passcode authentication regardless of the setting of the CC# Dual Authentication prompt.
For SIA CP-01 Compliance
CC# Dual Authentication must be left at its default value No.
CC# Dual Authentication Duration
Default:
Selection:
This is the amount of time allowed between the presentation of the user's credentials to the
reader and the entry of the user's passcode at the keypad. If this time elapses, the Dual
Authentication process is reset and authentication is denied.
F.01U.218.312 | 04 | 2012.03
Pass Code followed by [ENTER] (or [ENT]) key will momentarily
activate the CC# Enter Key Relay for 10 seconds.
Pass Code followed by [ENTER] (or [ENT]) key will restart Master Delay
Arm for all areas within the users authorized scope if the current area is
not disarmed. If the area is disarmed, then the arm state does not
change.
Set the keypad's configuration option of Command Center Dual Authentication to Yes.
Set the keypad's configuration option of Command Center Assign Door to the number
of the door.
Set the associated door's configuration option of Access Control CommandCenter #
Scope to the number of the keypad.
Review the areas listed in the configuration option Command Center Area(s) in Scope
for the keypad associated with the door. Ensure the doors Access Control Entry Area is
included in the area list.
A# Two Man Rule and A# Early Ambush must be disabled in the D# Entry Area for the
CC# Assign Door.
10 sec
10 to 45 (in 5-sec increments)
Program Entry Guide
D9412GV4/D7412GV4/D7212GV4
Bosch Security Systems, Inc.