186 en | SDI2 Modules
4.
5.
6.
D1260
1.
2.
3.
4.
5.
6.
Web Access Enable
Default:
Selection:
Yes
No
When enabled, the B420 allows authorized users to view and modify its configuration
parameters through a standard web browser.
Web Access Password
Default:
Selection:
Use this parameter to authorize web access to the B420 Network Communication Module.
NOTICE!
The password can be programmed with up to sixteen alphanumeric characters, including: A to
Z, 0 to 9, ?, &, @, -, *, +, $, #, _, /. Characters not listed are invalid and cannot be used for text.
NOTICE!
To disable the password check, enter a space (using the [Spacebar] key), as the password.
Firmware Upgrade Enable
Default:
Selection:
Yes
No
Use this parameter to enable or disable firmware upgrades on the B420.
Module Hostname (B420)
Use this parameter to create a module hostname. This is the hostname that represents the
module on the network. Once set, this hostname can be used to contact the control panel via
RPS over network. If enabled, a web browser can connect to this communication module at
this host name for the purposes of configuration and diagnostics.
F.01U.218.312 | 04 | 2012.03
Press [ENT] at the AES ENCRYPTION KEY option. If Encyption is disabled through RPS
or keypad programming, the keypad shows NO ENCRYPTION. If Encryption is enabled,
the default keypad value is NO ASSIGNED VALUE.
To change the setting, press [EDIT] and then enter the value using the number buttons.
Press [ENTER] to save the changes.
Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access the Tools Menu and
navigate to the Programming option.
Press [ENT] to enter the Programming option.
Press [ENT] at the Encryption option to enter it.
Press [ENT] at the AES Encryption Key option. If Encyption is disabled through RPS or
keypad programming, the keypad shows No Encryption. If Encryption is enabled, the
default keypad value is No Assigned Value.
To change the setting, press Edit softkey and then enter the value using the number
buttons.
Press the Save softkey to save the changes.
No
Yes or No
Web configuration is enabled
Web configuration is disabled
B42V2
Four to ten alphanumeric characters
No
Yes or No
Allows firmware upgrades to the B420 using the network.
Prevents firmware upgrades.
Program Entry Guide
D9412GV4/D7412GV4/D7212GV4
Bosch Security Systems, Inc.