D9412GV4/D7412GV4/D7212GV4
This prompt and the next six day-of-the-week prompts select the days of the week the
Opening and Closing windows are active.
Exceptions:
To prevent the windows from activating on certain days of the year, program Xept Holiday as
Yes, and enable at least one Holiday Index. When Xept Holiday is Yes, the window executes
on the days of the week programmed unless the Holiday Index designates the date as a
holiday.
If Opening and Closing Windows are only needed on certain days of the year, do not program
the windows to execute on any days of the week. Instead, program Xept Holiday as No and
select a Holiday Index with the days of the year you want the window to be active.
W# Monday
Default:
Selection:
W# Tuesday
Default:
Selection:
W# Wednesday
Default:
Selection:
W# Thursday
Default:
Selection:
W# Friday
Default:
Selection:
W# Saturday
Default:
Selection:
W# Open Early Begin
Default:
Selection:
Open Early Begin: This program item is one of three required to create an Opening Window.
To finish programming an Opening Window, Open Window Start and Open Window Stop must
be programmed.
The time programmed in the W# Open Early Begin field is the earliest time that the user is
allowed to open an area before the Opening Window Start time. If Opening and Closing
Reports are enabled, disarming the area between midnight and the open Early Begin time
generates an Opening Report.
Bosch Security Systems, Inc.
No
Yes or No
No
Yes or No
No
Yes or No
No
Yes or No
No
Yes or No
No
Yes or No
00:00
HH:MM (hours and minutes)
00:00 to 23:59
If A# Disable O/C in Window is set to Yes and the area is disarmed between the Open
Early Begin time and the Open Window Start time, the Opening event is sent with an
Early to Open modifier. If the Open Early Begin time is the same as the Open Window
Start time, no Opening Event is sent.
If Disable O/C in Window is set to No and the area is disarmed at any time, an Opening
Event is sent without an Early to Open or Late to Open modifier.