156 en | Schedules (Skeds)
Disarming the area between the Open Window Start and open Window Stop times creates a
local event in the control panel event log, but does not send the Opening Report to the central
station.
Disarming the area between the Open Window Stop time and before the next window's Open
Early Begin time (or midnight, whichever is earlier) generates an Opening Event with a Late to
Open modifier.
When configuring multiple windows to operate on the same day, ensure that they are added
to the system in chronological order. For example, if three windows are programmed to
execute on Tuesday, Window 1 (W1) must occur before Window 2 (W2), and Window 2 must
occur before Window 3 (W3).
NOTICE!
Avoid programming the Open Early Begin time before a time that is between another
window's Open Window Start and Open Window Stop times.
NOTICE!
Do not program a window to cross the midnight boundary.
Disabled windows have a beginning time of 00:00. If the entry for this prompt is 00:00, but
times are programmed for Open Window Start and Open Window Stop, the window is
disabled.
To disable the window, all hours and minutes spaces must be 00:00.
NOTICE!
Make time entries using a 24-hour clock. For example:
Midnight is entered as 00:00
7:00 AM is entered as 07:00
2:45 PM is entered as 14:45
11:59 PM is entered as 23:59
Reboot the control panel to activate today's window, if the window needs to activate on the
same day you program it.
W# Open Window Start
Default:
Selection:
Enter the time you want the control panel to start the Opening Window. The window goes into
effect at the beginning of the minute.
NOTICE!
Make time entries using a 24-hour clock. For example:
Midnight is entered as 00:00
7:00 AM is entered as 07:00
2:45 PM is entered as 14:45
11:59 PM is entered as 23:59
This program item is one of three required to create an Opening Window. To program an
Opening Window, Open Early Begin and Open Window Stop must also be programmed. Refer
to Section W# Open Early Begin, page 155 for explanations of report features.
F.01U.218.312 | 04 | 2012.03
00:00
HH:MM (hours and minutes)
Program Entry Guide
D9412GV4/D7412GV4/D7212GV4
Bosch Security Systems, Inc.