en | Panel and Area Wide Parameters
2
3
This program item determines when a passcode entry with L# Send Duress authority should
produce a duress alarm.
NOTICE!
Duress is enabled in Area Parameters by setting A# Duress Enable to Yes.
NOTICE!
The duress alarm activates when a user enters the duress passcode followed by the
termination keys ([ESC] or [ENT]).
For SIA CP-01 Compliance Duress Type must be set to 3.
Cancel Report
Default:
Selection:
Yes
No
A Cancel and Fire Cancel Report is created when a passcode is entered to silence an Alarm
Bell or a Fire Bell before the bell time expires.
For SIA CP-01 Compliance Duress Type this prompt must be set to Yes.
Call for Service Text
Default:
Selection:
Enter the text to display on a D1260 series keypad when the control panel is out of service.
On-site Authorization for Firmware Update
Default:
Selection:
Yes
No
Perform firmware updates using RPS. RPS Online Help includes instructions for using the
Firmware update feature.
NOTICE!
It is recommend that a full system test be performed whenever firmware is updated locally or
remotely.
F.01U.218.312 | 04 | 2012.03
Increase the last digit by 2 to generate an alarm. For example, if the
passcode is 6123, 6125 activates a duress alarm.
If the last digit of the passcode is 8, a duress alarm occurs when the
user enters 0 as the last digit of the passcode.
If the last digit of the passcode is 9, a duress alarm occurs when the
user enters 1 as the last digit of the passcode.
Send a Duress event when any Passcode with L# Send Duress set to
Yes is entered.
Yes
Yes or No
Send Cancel and Fire Cancel Reports according to routing.
Do not send Cancel and Fire Cancel Reports.
"Contact your dealer"
Twenty alphanumeric characters
No
Yes or No
Authorized personnel on-site must enter the authorization code at one
of the command centers at the designated time during the remote
firmware update process.
No on-site authorization is required.