Rps > [4] Rps Port Number Menu Parameters; Area Options Menu Parameters - Bosch B6512 Installation Manual

Hide thumbs Also See for B6512:
Table of Contents

Advertisement

110 en | Keypad Installer menu
4.
5.
6.
20.1.12
[3] RPS > [4] RPS Port Number menu parameters
In this menu, you can specify the destination port for outgoing RPS or Installer Services Portal
programming tool (available in Europe, Middle East, Africa, and China) session requests to the
specified IP address.
RPS Port Number
1.
2.
3.
4.
5.
6.
20.1.13

[4] Area Options menu parameters

This parameter enables or disables specified areas. Enabled areas must have assigned account
numbers. In this menu, you can turn on or off areas and assign area account numbers.
Notice!
Account numbers can contain characters 0 through 9, and B through F.
Area On
Account Number
Area State
1.
2.
3.
4.
5.
6.
2018.07 | 16 | F.01U.287.180
Use Previous or Next to toggle between the option to edit the address as an IPv4
address or as a hostname. Press Enter when the keypad shows the option you want to
edit.
Delete the existing characters, if necessary, and enter the new characters. For an IPv4
address, use
/Previous or
keys to enter the new numbers. For a hostname, press a number key repeatedly to scroll
through the number and letters shown on the key.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [3] RPS > [4] RPS Port Number.
Press Edit or Enter to edit the RPS port number.
Delete the existing number, if necessary, and then enter the new number.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
Area 1
Yes/No
______________
Enter the installer passcode, and then open the [1] Installer Menu.
Go to [1] Programming Menu > [4] Areas.
Use
/Previous or
/Next to go to the desired area.
Depending on keypad model:
Press Edit and then Yes or No.
-or-
Press Enter to edit the area and Enter to edit the Area On state for the selected area. Use
Previous or Next to toggle between the Yes and No options.
Press Save or Enter. The keypad shows Parameter saved.
Escape from the menu.
/Next to move to a different byte, and use the number
Area 2
Yes/No
______________
Installation Manual
Area 3
Area 4
Yes/No
Yes/No
______________
______________